您的浏览器版本过低,为保证更佳的浏览体验,请点击更新高版本浏览器

以后再说X

NEWS

Construction drawing of pipe truss

Shooting Angle: Shelf time:

The steel structure construction drawing is the result submitted by the design department to the construction unit after completing the design task. Its content includes component layout drawings, component diagrams, and general instructions. It is a technical document that guides the manufacturing and installation of steel structural components, and the manufacturing department of the steel structure will draw detailed construction drawings based on it. At the same time, the design drawings are also the basis for preparing the project budget and the archival materials after the completion of the project. Therefore, it is essential to be clear, precise, and accurate, and to express oneself in detail. A component layout diagram is an overall graphic representation of the position of various components, such as columns, steel structure pipe trusses, crane beams, wall frames, platforms, etc. Mainly used for the installation of steel structures, it is also the basis for structural fabrication. The construction drawing of steel structure pipe truss is a detailed drawing that expresses the manufacturing and installation requirements of all components of the steel structure pipe truss. Its main content and drawing points are: (1) The construction drawing of steel structure pipe truss is generally drawn according to the transportation unit. When the steel structure pipe truss is symmetrical, only half of the steel structure pipe truss can be drawn. The construction drawing should include a front view of the steel structure pipe truss, upper and lower chord plan views, as well as necessary side views, sectional views, and part drawings. (2) Draw a schematic diagram (single line diagram) of the steel structure pipe truss in the upper left corner of the drawing at an appropriate scale. The geometric axis dimensions of the steel structure pipe truss members should be indicated on the left half span, and the internal force design values of the members should be indicated on the right half span. The arch height of the steel structure pipe truss * should also be indicated (not necessarily shown on the steel structure pipe truss diagram). In the center of the drawing are the front and upper and lower chord plan views of the steel structure pipe truss. The material list is located in the upper right corner, which includes the numbers, specifications, lengths, quantities (both positive and negative), and weights of all rods and components. This information is used for batching and calculating steel usage, and can also serve as a reference for equipping lifting and transportation equipment. (3) The construction drawing of steel structure pipe truss is usually drawn using two scales. The axis size of steel structure pipe truss members is generally drawn at a scale of 1:20~1:30, while the node size and member section size are drawn at a scale of 1:10~1:15. More emphasis can be placed on important nodes and special components. Clearly express the detailed dimensions of the nodes. (4) The construction drawings should indicate the model and main geometric dimensions of each component, including machining dimensions (preferably multiples of 5 mm), positioning dimensions, hole positions, and requirements for factory manufacturing and on-site installation. The positioning dimensions mainly include: the distance between the end of each member and the edge of the node plate (up, down, left, right), the distance between the axis and the back of the angle steel, etc. The position of bolt holes should meet the requirements of bolt arrangement. The installation requirements for factory manufactured construction sites, including component chamfering, limb cutting, edge cutting, hole diameter, and weld size, should be indicated in the construction drawings. The welding seams and bolts installed on the construction site should be marked with their symbols to accommodate the splicing of transportation units. (5) Each component in the construction drawing should be numbered in detail, arranged in order of priority, top, bottom, left, and right. When identical components are labeled with the same number, such as two components with identical shapes and sizes, only due to differences in opening positions or cutting angles, making the two components mirror symmetric, the same number can be used and only the positive and negative characters need to be marked in the material list to indicate the difference. (6) There should also be textual explanations on the construction drawings, which mainly include:; The steel grade, welding rod type, welding method, quality requirements, dimensions of welds and bolt holes not indicated in the drawing, rust prevention treatment methods, as well as transportation, installation, and manufacturing requirements. In addition, some content that is difficult to express clearly in construction drawings but should be expressed clearly in words can also be explained in words. Section 9.8 Design Features of Single story Industrial Buildings with Cranes 9.8.1 Working level of crane Cranes are common lifting equipment in factories. According to the heavy usage of cranes (i.e. the number of times they are used and the size of the load), the standard GB 3811-83 "Code for Design of Cranes" divides them into eight working levels, called Al~A8. Many literature tends to classify cranes into four working levels: light, medium, heavy, and extra heavy, and their corresponding relationships are shown in the table. Single story factory steel structures are generally supported by horizontal frames, which are typically composed of columns and steel pipe trusses (beams). The connection between the crossbeam and the column can be hinged or rigid. Correspondingly, the horizontal frame is called a hinged frame (also known as a bent frame) or a rigid frame. For some factories with high stiffness requirements (such as double decker cranes, equipped with hard hook cranes, etc.), especially for single span heavy-duty factories, rigid frame should be used. When there are multiple spans, especially when the lifting capacity of the crane is not very large and a lightweight enclosure structure is used, it is advisable to use articulated frames. The longitudinal components such as roof panels or purlins, brackets, and roof supports are connected to each other between the various horizontal frames. Therefore, the frame is actually a spatial working structure, and it should be calculated according to spatial work to be more reasonable and economical. However, due to the complexity and workload of calculations, it is usually simplified to a single planar frame (Figure 9.8.1) for calculation. The division of the framework calculation should be determined based on the arrangement of the column grid (Figure 9.1.2), so that each column * in the longitudinal direction has one less column participating in the framework work, and columns with unfavorable stress * should be included in the calculation unit. For a single-layer factory steel structure with equal column spacing, only one frame is calculated. For calculation units with extracted columns, the standard for dividing calculation units is generally 347 based on the maximum column spacing. The boundary can be determined by the line of column spacing or the axis of the column. If the latter is used, only half of the stiffness of the column should be considered for the edge columns of the calculation unit, and only half of the load acting on the column should be considered. For a transverse frame composed of lattice beams and stepped columns (with lattice columns as the lower columns), the influence of the deformation of the web members or struts of the steel structure pipe truss beams and lattice columns is generally considered. The moment of inertia (calculated based on the average height of the steel structure pipe truss beams with height changes) is multiplied by a reduction factor of 0.9 to simplify it into a solid web beam and a solid web column. For the transverse frame with column top rigid connection, when the following conditions are satisfied, it can be approximated that the stiffness of the crossbeam under horizontal load is infinite

Products

Contact Us

Phone: +8613091156750

E-mail: Emily@zongrunsteelpipe.com

Add:Hope New District of Mengcun County, Cangzhou City, Hebei Province—recognized as the “Capital of Steel Pipes and Fittings in China.”